SYCON in comparison
Find the right analyzer for your application
Features
- Functional principle:
- Limit value:
- Parameters:
- Units:
- Reagent consumption:
- Measuring point/range:
(see Reagent)
- Fully automatic operation
- BOB - FunctionalityTheanalyzer indicates whether there is a sufficient supply of Reagent for at least the next 72 hours.
- Diagnostic program
- Time-controlled analysis interval
- Quantity-controlled analysis interval
- Measured value log on SD card
- Modbus RTU interface
- Analog output (4 ... 20 mA)
Relay functions- Limit value 1
- Limit value 2
- Analysis active / cooling water
- Operational readinessWhen the analyzer is switched on, one of the relays picks up. This allows an external control system to recognize whether the device is ready for operation or whether there is a fault such as a device malfunction, power failure or line defect.
- BOB Warning
Input functions- Flow monitor
- Interval resetRecommended for pendulum softening systems. A running analysis can be canceled via the input when switching to the other water softener. This ensures that the measurement result is always assigned to the correct system by the control unit.
- External analysis start
- Analysis termination
- Water meter
All analyzers
- BASIC -

SYCON 2602
- Limit value device
The analyzer determines whether a water hardness limit value has been reached (good/bad measurement).
Limit value is determined by the Reagent used.
- determined by Reagent
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.1 ml / analysis
min. 5000 analyses / 500 ml - Reagent
- The analyzer indicates whether there is a sufficient supply of Reagent for at least the next 72 hours.
- When the analyzer is switched on, one of the relays picks up. This allows an external control system to recognize whether the device is ready for operation or whether there is a fault such as a device malfunction, power failure or line defect.
- Recommended for pendulum softening systems. A running analysis can be canceled via the input when switching to the other water softener. This ensures that the measurement result is always assigned to the correct system by the control unit.
Sycon 2602
- BUDGET -
SYCON 2702
- Titration device
The analyzer measures the water hardness within a certain measuring range and gives an accurate result.
The measuring range is determined by the Reagent used. - an adjustable limit value
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.05 ml / analysis
min. 10000 analyses / 500 ml - Reagent
- The analyzer indicates whether there is a sufficient supply of Reagent for at least the next 72 hours.
- When the analyzer is switched on, one of the relays picks up. This allows an external control system to recognize whether the device is ready for operation or whether there is a fault such as a device malfunction, power failure or line defect.
- Recommended for pendulum softening systems. A running analysis can be canceled via the input when switching to the other water softener. This ensures that the measurement result is always assigned to the correct system by the control unit.
Sycon 2702
- PREMIUM -
SYCON 2802
- Titration device
The analyzer measures the water hardness within a certain measuring range and gives an accurate result.
The measuring range is determined by the Reagent used. - Two adjustable limit values
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.05 ml / analysis
min. 10000 analyses / 500 ml - Reagent
- The analyzer indicates whether there is a sufficient supply of Reagent for at least the next 72 hours.
- When the analyzer is switched on, one of the relays picks up. This allows an external control system to recognize whether the device is ready for operation or whether there is a fault such as a device malfunction, power failure or line defect.
- Recommended for pendulum softening systems. A running analysis can be canceled via the input when switching to the other water softener. This ensures that the measurement result is always assigned to the correct system by the control unit.
Sycon 2802
Features:
- Functional principle:
- Limit value:
- Parameters:
- Units:
- Reagent consumption:
- Measuring point/range:
(see Reagent)
- Fully automatic operation
- BOB - Functionality1
- Diagnostic program
- Time-controlled analysis interval
- Quantity-controlled analysis interval
- Measured value log on SD card
- Modbus RTU interface
- Analog output (4 ... 20 mA)
Relay functions- Limit value 1
- Limit value 2
- Analysis active / cooling water
- Operational readiness
- BOB Warning
Input functions- Flow monitor
- Interval Reset2
- External analysis start
- Analysis termination
- Water meter
All analyzers
- BASIC -

SYCON 2602
- Limit value device
The analyzer determines whether a water hardness limit value has been reached (good/bad measurement).
Limit value is determined by the Reagent used. - determined by Reagent
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.1 ml / analysis
min. 5000 analyses / 500 ml - Reagent
to the Sycon 2602
- BUDGET -
SYCON 2702
- Titration device
The analyzer measures the water hardness within a certain measuring range and gives an accurate result.
The measuring range is determined by the Reagent used. - an adjustable limit value
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.05 ml / analysis
min. 10000 analyses / 500 ml - Reagent
to the Sycon 2702
- PREMIUM -
SYCON 2802
- Titration device
The analyzer measures the water hardness within a certain measuring range and gives an accurate result.
The measuring range is determined by the Reagent used. - Two adjustable limit values
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.05 ml / analysis
min. 10000 analyses / 500 ml - Reagent
to the Sycon 2802